PPM-WCY68-P500A Very Low Differential Pressure Transducer

Products

Search

Popular products

PPM-WZPB Small Temperature Transmitter
Number of views:
1000
Keywords:
小巧温度变送器
温度变送器
编号:
PPM-S313A
PPM-S313A High Temperature Pressure Core
编号:
PPM-S313A
Number of views:
1000
Keywords:
A高温压力芯体
编号:
PPM-T9406
PPM-T9406 Bluetooth Type Medium and High Pressure Wireless Pressure Transmitter
编号:
PPM-T9406
Number of views:
1000
Keywords:
蓝牙型中高压无线压力变送器
0.00
编号:
PPM-T330D
PPM-T330D Low Temperature Pressure Sensor
0.00
编号:
PPM-T330D
Number of views:
1000
Keywords:
低温压力传感器

PPM-WCY68-P500A Very Low Differential Pressure Transducer

PPM-WCY68-P500A Very Low Differential Pressure Transducer
Retail price
0.0
Market price
0.0
Number of views:
1000
Product serial number
Agent Brand:
Setra
Quantity
-
+
Stock:
0
Keyword:
差压传感器
差压传感器变送器
进口传感器
Currently out of stock
1
Product description

pressure transducers sense gauge(static) or differential pressure and convert this pressure difference to a proportional current or voltage output. The 268 series is offered with a high level analog 0 to 5 VDC, 0 to 10 VDC or 4-20mA output. The 268MR offers multi-range capability and field configurable output. The Model 268 is packaged in a die-cast aluminum enclosure that is specifically designed for IP65 service to withstand environmental effects. Used in Building Energy Management Systems, the 268 and 268MR pressure transducers are available for air pressure ranges  as low as 0.1 in W.C. (25 Pa) full scale to 100 in. W.C. (25 kPa) full scale. Static accuracy is ±1% full scale in normal ambient temperature environments.

The 268 series utilizes an improved all stainless steel micro-tig welded sensor, which is enclosed in a welded stainless steel body. The tensioned stainless steel diaphragm and insulated stainless steel electrode, positioned close to the diaphragm, form a variable capacitor. As the pressure increases or decreases, the capacitance changes. The change in capacitance is detected and converted to a linear DC electrical signal by Setra’s unique electronic circuit. The micro-tig welded tension sensor allows up to 10 psi overpressure(in either direction), with no damage to the unit.

The improved sensor design also allows the Model 268MR version to have 6 field selectable pressure ranges (bi-directional and unidirectional) in one unit. The simple flip of a dip switch enables the user to easily field calibrate the unit with minimal effort. Explosion- proof units are approved for ia II CT4.

 

Technical Parameters :

Parameter

Accuracy RSS*

(at constant temp.)

Standard

±1.0%FS

Optional

±0.4%FS

Optional

±0.25%FS

Non-Linearity (BFSL)

±0.98%FS

±0.33%FS

±0.20%FS

Hysteresis

±0.20%FS

±0.20%FS

±0.20%FS

Non-Repeatability

±0.05%FS

±0.05%FS

±0.05%FS

Thermal Effects**

Compensated Range °F(°C)

+40 to +150 (+5 to +65)

 

 

Zero/Span Shift %FS/ °F(°C)

±0.033 (±0.06)

 

 

Maximum Line Pressure

10 PSI

 

 

Overpressure

10 PSI in Positive or Negative Direction

 

 

Warm-up Shift

±0.1% FS Total

 

 

Position Effect***

Range

Zero Offset (%FS/g)

 

0 To 25Pa

2.1

 

0 To 250Pa

0.22

 

0 To 1250Pa

0.14

 

0 To 7500Pa

0.06

 

Physical Description

Case

IP65 die-cast aluminum enclosure

 

 

Electrical Connection

Screw Terminal Strip Inside of Case

 

 

Electrical Termination

PG-9

 

 

Zero and Span Adjustment

Accessible Inside of Case

 

 

Pressure Fittings

3/16" O.D. Barbed Brass for 1/4" Push-On Tubing (Standard)

 

 

Mounting

2 Mounting Tabs with 0.18" Holes

 

 

Weight (approx.)

348 grams

 

 

Pressure Media

Typically Air or Similar Non-Conducting Gases.

 

 

Environmental Data Temperature Operating* °F (°C)

Storage °F (°C)

0 to +150 (-18 to +65)

-65 to +180 (-54 to +82)

 

 

Electrical Data (Current)

Circuit

2-Wire

 

 

Output*

4 to 20 mA**

 

 

Bidirectional Output at Zero

12 mA

 

 

External Load

0 to 800 Ohms

 

 

Minimum loop supply voltage

(VDC) = 9 + 0.02 x (Resistance of receiver plus line)

 

 

Maximum loop supply voltage

(VDC) = 30 + 0.004 x (Resistance of receiver plus line)

 

 

Re-Ranging (268MR only)

4 Position Dip Switches (located inside case)

 

 

 

Dimensions in mm :

Applications :

●Power Plant

●Energy Management Systems

●Orifice Plate Flow Measure

●Oven Pressurization and Furnace Draft Controls

 

Scan the QR code to read on your phone
We could not find any corresponding parameters, please add them to the properties table

Related product recommendation

Oil Condition Monitoring Sensors PPM-HLF-2
Oil Condition Monitoring Sensors PPM-HLF-2
3in1 Oil Condition Monitoring Sensor PPM-HLV-2
3in1 Oil Condition Monitoring Sensor PPM-HLV-2
 Online moisture in oil transmitter PPM-HLW-2B
Online moisture in oil transmitter PPM-HLW-2B

Contact Us

 

E-mail:info@csppm.com

ADD: 404, block a, building 7, international enterprise center, No. 188, middle environmental protection road, Yuhua District,

Changsha, Hunan Province

公众号二维码

Sweep It

Copyright © 2020 CHANG SHA TAIHE ELECTRONIC EQUIPMENT CO.LTD   湘ICP备19039544号    BY:xinnet

Copyright © 2020 CHANG SHA TAIHE ELECTRONIC EQUIPMENT CO.LTD   湘ICP备19039544号    BY:xinnet