Products
-
Pressure Sensors
-
Level Sensors
-
Force Sensors
-
Temperature Sensors
-
Dispalcement Sensors
-
Flow Meters
-
Indicators
-
Ultra-low Temperature Sensors
-
Density Sensors
-
Acceleration Sensors
-
Tension Sensors
-
Piezoelectric Sensors
-
Torque Sensors
-
Pressure switch
-
Military Sensors
-
Differential Pressure Sensors
-
Import Series
Popular products
PPM-TC1CEW Series of Digital Smart Meters
Designed with high precision for various industrial measurement and control
0.05 level accuracy, measurement and control speed can be set from 10 times to 400 times per second.The display range is -99999 to 99999.
Analog universal input, connected to all sensors through setting selection.
Optional alarm output 1-4. Including upper limit of measured value, lower limit of measured value, upper limit of deviation, lower limit of deviation, upper limit of deviation absolute value, upper limit of deviation absolute value, fault alarm seven basic alarm modes and four standby alarm modes.
Input signal fault processing, measurement value clearing, peak and valley value acquisition, 10-segment polyline correction and other functions.Optional transmission and communication.
Product Selection Table :
Content |
Code Description |
|||||||||
TC1CEW- |
0.05 level measurement accuracy, measurement and control speed can be set from 10 times / second ~400 times / second |
|||||||||
Dimension |
AH |
160x80x125 Horizontal Hole size:152 x76(mark①) |
||||||||
CH |
96x48x82 Horizontal Hole size:92x45 (mark②) |
|||||||||
Panel Specification |
Single 6-digit LED display |
|||||||||
Alarm (option)(250VAC/3A ,Resistive load) |
AH |
T1-T4 |
1 ~ 4 points alarm relay output, all are normally open + normally closed dual contacts |
|||||||
01-04 |
Alarm is OC gate output (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||
CH |
T1-T2 |
1 ~ 2 points alarm relay output, all are normally open + normally closed dual contacts |
||||||||
01-02 |
Alarm is OC gate input (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||
T3 |
3-point alarm relay output, all single normally open contacts |
|||||||||
03 |
Alarm is OC gate output (voltage should be less than 40V DC, current should be less than 40mA) |
|||||||||
Contact input (optional) |
K |
1 point external digital input for clearing |
||||||||
Transmitter(option)(resolution: 1/3000; load capacity: 600Ω) (Suitable for transmission speed below 200 times) |
Al |
Current output(4~20)mA、(0~20) mA, (0~10) mA |
||||||||
A2 |
Voltage output(0~5) V. (1~5)V |
|||||||||
A3 |
Voltage output(0~10) V |
|||||||||
A4 |
Voltage output(-5V~+5V) |
|||||||||
A5 |
Voltage output(-10V-+10V) |
|||||||||
Fast transfer(optional) |
F |
Applicable to the transmission speed of measurement and control speed 200 times / second and above |
||||||||
External power supply (option) |
B1 |
Below 24V±5% 50mA |
||||||||
B2 |
Below 12V±5% 50mA |
|||||||||
B3 |
Below10V±5% 50mA |
|||||||||
Communication (option) (Optional via instrument parameters: Modbus-RTU or TC-ASCII communication protocol) |
SI |
RS232 Interface (only for AH dimension) |
||||||||
S2 |
RS485 interface |
|||||||||
Power Specification |
V0 |
100-240 V AC 50/60 Hz |
||||||||
VI |
10-24V AC 50/60 Hz ; 10-24V DC |
Related product recommendation
Contact Us
E-mail:info@csppm.com
ADD: 404, block a, building 7, international enterprise center, No. 188, middle environmental protection road, Yuhua District,
Changsha, Hunan Province
Sweep It
Copyright © 2020 CHANG SHA TAIHE ELECTRONIC EQUIPMENT CO.LTD 湘ICP备19039544号 BY:xinnet